ELECTRO-STATIC DISCHARGE
To avoid static discharge from production line equipment, the equipment and everything on it
must be grounded correctly. While it is not Domino's responsibility to maintain the customer's
equipment, the customer must be aware of the importance of grounding. At the time of
installation of the printer, the Domino (or Domino distributor) technician should ensure that the
line the printer is installed on is appropriately grounded. This means that all metallic items within
12 inches (300mm) of the print head location must be securely grounded. This should be
checked with respect to the print head chassis ground using an Ohm Meter, DVM or another
suitable device. It is essential that grounding is checked periodically and that if the printer is
relocated to a dierent production line, then the new production line is properly grounded.
Additional static dissipating devices, such as static brushes on the line, etc. are recommended.
HEALTH AND SAFETY
EPT077343 EN - Issue 1 - 11 November 2022 15