Error Severity
Level
(Function 39)
CORRECTIVE ACTIONPROBABLE CAUSEDESCRIPTION
ERROR
CODES
1Replace WIPThe WIP has reported that
amount of jitter pulses
while the meter was idle
has exceeded the number
specified in function 17.01
Jitter limit reached on an
idle WIP
51
Check for product
crossflow
52-53
1Replace check valveThe WIP has reported that
amount of reverse pulses
while the meter was idle
has exceeded the number
specified in function 16.03.
Reverse flow limit reached
on idle meter.
54
Unequal, too high or too
low fuel pressures.
55
0Replace flow control
valve
The WIP has reported that
amount of forward pulses
while the meter was idle
has exceeded the number
specified in function
19.14/19.24.
Forward flow limit reached
on an idle meter.
56
Unequal, too high or too
low fuel pressures.
57
Replace WIP.WIP is not communicating
with iGEM. A communica-
tion timeout occurred while
the meter was in use dur-
ing a transaction.
Communication lost to an
in-Transaction WIP
58
Replace ISB or cables.
0Replace WIP.WIP is not communicating
with iGEM. A communica-
tion timeout occurred while
the meter was idle.
Communication lost to an
idle WIP
59
Replace ISB or cables.
60-61
1Re-calibrate.Volume exceeded expect-
ed limit during calibration
WIP is outputting jitter dur-
ing calibration
62
Replace WIP.
63-66
0WIP has been calibratedWIP calibration OK bit sta-
tus changed
67
0WIP door was
opened/closed
WIP calibration door status
changed
68
0WIP last calibration suc-
cessful
WIP last calibration status
changed
69
WM048523 Rev 08 01/2019 173
9 Error Codes, Problem Symptoms and Solutions - NA