Error Severity
Level
(Function 39)
CORRECTIVE ACTIONPROBABLE CAUSEDESCRIPTION
ERROR
CODES
1Replace valve or cables.Start of flow not detected
for the amount of time
specified in function 17.02
(flow never started)
Timeout limit reached for
No Flow.
70
Replace pump/motor
control relay.
Replace nozzle.
Replace iGEM computer
1Consecutive no flow errors
have been detected for the
number of fillings specified
in function 17.04
n Consecutive No Flow
Timeouts
71
1Replace valve or cables.Flow was lost for the
amount of time specified in
function 17.03 (flow lost
during sale)
Timeout limit reached for
Flow Lost.
72
Replace pump/motor
control relay.
Replace nozzle.
Replace iGEM computer
1Replace valve or cables.Consecutive flow lost er-
rors have been detected
for the number of fillings
specified in function 17.04
n Consecutive Flow Lost
timeouts.
73
Replace pump/motor
control relay.
Replace nozzle.
Replace iGEM computer
1Replace valve or cables.Unfinished fillingSale terminated before
preset limit reached
74
Replace pump/motor
control relay.
Replace nozzle.
Replace iGEM computer
1Replace valve or cables.Consecutive sales did not
reach the preset limit.
Number of sales is speci-
fied in function 17.06
n Consecutive unfinished
fillings
75
Replace pump/motor
control relay.
Replace nozzle.
Replace iGEM computer
0DEF temperature change
signal received
DEF Low temperature
Event #’s Event #1 = Low
temp, Event #2 = Low
temp cleared
76
174 WM048523 Rev 08 01/2019
9 Error Codes, Problem Symptoms and Solutions - NA