Error Severity
Level
(Function 39)
CORRECTIVE ACTIONPROBABLE CAUSEDESCRIPTION
ERROR
CODES
1Reload correct dis-
penser template
0- Additive configuration
conflict
Additive Error
Device #'s:
77
Check CAN connections
and termination jumpers
1- No response from Addi-
tive Controller board
0 = Configuration Error
1 = CAN Communication
Error
Add additive
Close well door after fill-
ing the tank
2- Tank reported empty
3- Tank door reported
open
2 = Tank Empty
3 = Tank Door Open
Check the LED codes
on the Driver module
4- Additive motor not turn-
ing
4 = Motor Failure
5 = Injection Fell Short
Replace controller board5- Additive Injector not
able to keep up with flow
rate
6 = Flow Error
Check for pump or addi-
tive line leaks. Repair/
replace as necessary.6- Additive flow not detect-
ed
78-79
1Replace iGEM computerInternal iGEM board errorSoftware exception encoun-
tered: Mail buffer pool ex-
hausted
80
81-89
1Replace FTB.iGem has lost communica-
tion with the FTB
ATC - Fuel Temperature
Board communication fail-
ure. iGEM lost comm with
FTB
90
Replace FTB cable.
Replace iGEM computer
1Replace temperature
probe.
Defective or out of range
probe detected by the FTB
ATC - Fuel Temperature
Board - temperature probe
shorted
91
Replace FTB.
1Replace temperature
probe.
Defective or out of range
probe detected by the FTB
ATC - Fuel temperature
Board - temperature probe
open
92
Replace FTB.
1Replace FTBInvalid fuel type selected
in the FTB.
ATC - Fuel Temperature
Board - Invalid type error
93
Internal FTB error.
3Verify/correct ATC pro-
gramming. Function 50
ATC function data pro-
grammed incorrectly
ATC configuration error
94
1Replace FTBFTB detected auto-calibra-
tion out of range.
ATC - Fuel temperature
board calibration error
95
Internal FTB error
4See Function 56Door sensor switch activity
detected while armed
Dispenser security
breached:
96
Device #1 = Bezel door
Device #2 = Hydraulic door
WM048523 Rev 08 01/2019 175
9 Error Codes, Problem Symptoms and Solutions - NA