ClassificationDescriptionError/EventNo.
BOnly in V11.xx.WIP calibration data mismatch60
Calibration constant, calibration curve number or
calibration curve are different in XWIP and in iGem.
This occur if one or more XWIP’s AND/OR the iGEM
board is replaced on a pump with XFLO meters.
CConfiguration of iGem is incorrect.General configuration error61
1) Every pump needs at least a primary meter as-
signed to operate OK.
CWIP is exchanged.WIP serial number mismatch62
N/AN/AN/A63-65
CLPG WIPs needs to be calibrated.LPG calibration factor mis-
match
66
To calibrate: 1) Enter maintenance mode and set
parameter F16.05=1. 2) Remove calibration magnet
from meter to be calibrated. 3) Exit and save. 4)
Return calibration magnet.
N/AN/AN/A67-69
BFilling was started but no fuel has been dispensed
for configurable time. ( -> F17.03 )
No Flow Timeout70
CConfigured number of maximum consecutive No
Flow events has been reached ( -> F17.04 )
Consecutive number of no flow71
BFlow was lost for configured maximum time ( ->
F17.03 )
Flow Lost Timeout72
CConfigured number of maximum consecutive Flow
Lost events has been reached ( -> F17.05 ).
Consecutive number of lost
flow
73
BFilling ended before preset or prepay limit was
reached.
Unfinished filling74
BConfigured number of unfinished fillings has been
reached ( -> F17.06 )
Consecutive number of unfin-
ished fillings.
75
CConsecutive number of fillings with Hydro Filter
Clogged (F44)
Hydro Filter Clogged76
ABattery for non-volatile RAM is < 2,5 VBattery level Low77
BFlowrate > 80 lpm on LPG nozzleLPG Excess Flowrate78
HAn error has been triggered in CAN driverCAN bus error79
BMail buffer of RTOS is exhaustedRTOS mail buffer exhausted80
FF03 is not programmed and pump running in stan-
dalone mode
F03 not programmed81
FF04 is not programmed and pump running in stan-
dalone mode
F04 not programmed82
FF05 is not programmed and pump running in serial
mode
F05 not programmed83
FF06 is not programmed and pump running in serial
mode
F06 not programmed84
FF37 (pump model type) is not programmedF37 not programmed85