Replace the three O-rings in the meter base. Fig 15.31.
Figure 15.31: Replace three o-rings
9
Install new meter in reverse order. Note: When installing new meter, it is easier if you put the
middle screws in meter first before lowering the meter down into position.
10
Replace valve O-ring. Fig 15.32.
Figure 15.32: Replace valve o-ring
11
Reinstall valve into meter.
12
Rotate valve retaining plate over the valve and re-secure the 10 mm screws.
13
Reinstall WIP onto meter.
14
Reset the emergency sheer valve.
15
Turn on power to the dispenser and test operation.