OEM Drive Limits (4.4.4)
Maximum Forward Speed Limit
0 - 100 %
100 %
Maximum Reverse Speed Limit
0 - 100 %
100 %
Minimum Forward Speed Limit
0 - 100 %
0 %

Minimum Reverse Speed Limit
0 - 100 %
0 %

Acceleration Limit
0 - 100 %
100 %
Deceleration Limit
0 - 100 %
100 %
Motor Management (4.4.5)
Motor Protection
No / Yes
No
ThermalRollbackStart
0 70°C
70°C

ThermalRollbackEnd
70 80°C
80°C

Motor Continuous Current
90A (DS90)
120A (DS120)
160A (DS160)
36A (DS90)
48A (DS120)
64A (DS160)

Motor Heating Time
1 - 255s
20s

Motor Cooling Time
4 - 1020s
32s

Motor Reverse
No / Yes
No

Load Compensation
0 - 225mΩ
DS90:
60mΩ
DS120:
40mΩ
DS160:
28mΩ
Maximum Load Compensation
0 - 225mΩ
DS90, DS120:
200mΩ
DS160:
100mΩ
Load Compensation Damping
15 60%
50%

Remembered Load Compensation
15 60%
50%

Current Limit
DS90:
0-90A
DS120:
0-120A
DS160:
0-160A
DS90:
90A
DS120:
120A
DS160:
160A
Boost Current
DS90:
10A
DS120, DS160:
20A
DS90:
0A
DS120, DS160:
20A
Boost Time
10s
DS90:
0s
DS120:
3s
DS160:
5s

Stall Timeout
0 - 51s
15s
Motor Testing
None
Open
Short
All
Short

Maximum Motor Voltage
0 - 64V
26.2V

Table of Contents

Other manuals for Dynamic RHINO2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynamic RHINO2 and is the answer not in the manual?

Dynamic RHINO2 Specifications

General IconGeneral
BrandDynamic
ModelRHINO2
CategoryController
LanguageEnglish

Related product manuals