Replacement
Behavior of replacement function
Setting Description
Signal > Tick checkbox to activate replacement function if current measurement value exceeds or
falls below the defined limit for signal strength.
> Enter signal limit in dB
less = replacement function is activated if current measurement value falls below the defined
limit value.
greater = replacement function is activated if current measurement value exceeds the defined
limit value.
Value for waterlevel
H
HWater
Hair
> Select which water level parameter will be used for checking if replacement function will be
applied.
Replacement function calculation
none
> Tick checkbox if no replacement function shall be used for discharge calculation.
from
measurements
> Tick checkbox to calculate Q from W/Q (water level / discharge) relation.
Programming
Page 58 March 2021HYB-UM-03155-EN-03