Type ID Type ID Type ID
User Code 23 48 User Code 9 on ELDES Cloud Services 66 User Code 27 on ELDES Cloud Services 84
User Code 24 49 User Code 10 on ELDES Cloud Services 67 User Code 28 on ELDES Cloud Services 85
User Code 25 50 User Code 11 on ELDES Cloud Services 68 User Code 29 on ELDES Cloud Services 86
User Code 26 51 User Code 12 on ELDES Cloud Services 69 User Code 30 on ELDES Cloud Services 75
User Code 27 52 User Code 13 on ELDES Cloud Services 70 KeyFob 1-KeyFob 16 76-
91
User Code 28 53 User Code 14 on ELDES Cloud Services 67 Arm/Disarm by Zone Z1-Z80 163-
243
User Code 29 54 User Code 15 on ELDES Cloud Services 68
User Code 30 55 User Code 16 on ELDES Cloud Services 69
Remote Code (EGR100) 56 User Code 17 on ELDES Cloud Services 70
Master Code on ELDES Cloud Services 57 User Code 18 on ELDES Cloud Services 71
User Code 1 on ELDES Cloud Services 58 User Code 19 on ELDES Cloud Services 72
User Code 2 on ELDES Cloud Services 59 User Code 20 on ELDES Cloud Services 73
User Code 3 on ELDES Cloud Services 60 User Code 21 on ELDES Cloud Services 74
User Code 4 on ELDES Cloud Services 61 User Code 22 on ELDES Cloud Services 75
User Code 5 on ELDES Cloud Services 62 User Code 23 on ELDES Cloud Services 76
User Code 8 on ELDES Cloud Services 65 User Code 26 on ELDES Cloud Services 79
Disable data message
EKB2
Menu path:
Burglary alarm/restore: OK → iiii → OK → MS SETTINGS → OK → DATA MESSAGES 1 → OK →
BURGLR ALM/REST EV → OK → DISABLE → OK
Mains power loss/restore: ... → MAIN POWER L/R EV → OK → DISABLE → OK
Armed/disarmed by user: ... → ARM/DISARM EVENT → OK → DISABLE → OK
Battery failed: ... → BATTERY FAILED → OK → DISABLE → OK
Battery dead or missing/battery connection restore: ... → BATTERY DEAD/MISS → OK →
DISABLE → OK
Test event: ... → TEST EVENT → OK → DISABLE → OK
Tamper alarm/restore: ... → TAMPER ALM/REST EV → OK → DISABLE → OK
Instant Silent zone alarm/restore: ... → INST SILENT EV → OK → DISABLE → OK
System started: ... → SYSTEM STARTED EV → OK → DISABLE → OK
Fire alarm/restore: ... → FIRE ALM/REST EV → OK → DISABLE → OK
24-Hour zone alarm/restore: ... → 24H ALM/REST EVENT→ OK → DISABLE → OK
Low battery: ... → LOW BATTE RY EVENT → OK → DISABLE → OK
Temperature risen: ... → TEMP HIGH EVENT → OK → DISABLE → OK
Temperature fallen: ... → TEMP LOW EVENT → OK → DISABLE → OK
Wireless signal loss/restore: ... → WLESS SIGN L/R EV → OK → DISABLE → OK
Disarmed by user (Duress code): OK → iiii → OK → MS SETTINGS → OK → DATA MESSAGES 2 →
OK → DISARM DURESS EV → OK → DISABLE → OK
SGS code entered: ... → ARM/DARM SGS EVENT → OK → DISABLE → OK
Armed by user (partial arm): ... → ARM PARTIAL EV → OK → DISABLE → OK
Siren fail/restore: ... → SIREN FAIL/REST EV → OK → DISABLE → OK
RF jammer detected/RF jamming stopped: ... → RF JAMMER DETECTED → OK → DISABLE → OK
Date/time not set: ... → DATE/ TIME NOT SET → OK → DISABLE → OK
GSM connection failed: ... → GSM CONNECT FAILED → OK → DISABLE → OK
GSM/GPRS antenna fail/restore: ... → GSM ANT FAIL/REST → OK → DISABLE → OK
System shutdown: ... → SYSTEM SHUTDOWN EV → OK → DISABLE → OK
Communication bus fail/restore: ... → COMM BUS FAIL/RST → OK → DISABLE → OK
IP connection failed: ... → GPRS CONNECT FAIL → OK → DISABLE → OK
Zone bypassed/activated: ... → ZONE BYPASS→ OK → DISABLE → OK
CO sensor lifetime exceeded: ... → CO SENS LFTIME EXC→ OK → DISABLE → OK
CO level critical: ... → CO LEVEL CRITICAL → OK → DISABLE → OK
Report/Control zone triggered/restored: ... → REPORT→ OK → DISABLE → OK
EKB2
Armed/disarmed in STAY mode: OK → iiii → OK → MS SETTINGS → OK → DATA MESSAGES 3 →
OK→ ARM/DARM STAY EV → OK → DISABLE → OK
Conguration via remote connection started: ... → CFG VIA REMOTE EV → OK → DISABLE → OK
Panic/Silent zone alarm/restore: ... → PA/SIL ALM/REST EV → OK → DISABLE → OK
Value: iiii – 4-digit installer code.