Enable data message
EKB2
Menu path:
Burglary alarm/restore: OK → iiii → OK → MS SETTINGS → OK → DATA MESSAGES 1 → OK →
BURGLR ALM/REST EV → OK → ENABLE → OK
Mains power loss/restore: ... → MAIN POWER L/R EV → OK →ENABLE → OK
Armed/disarmed by user: ... → ARM/DISARM EVENT → OK → ENABLE → OK
Battery failed: ... → BATTERY FAILED → OK → ENABLE → OK
Battery dead or missing/battery connection restore: ... → BATTERY DEAD/MISS → OK →
ENABLE → OK
Test event: ... → TEST EVENT → OK → ENABLE → OK
Tamper alarm/restore: ... → TAMPER ALM/REST EV → OK → ENABLE → OK
Instant Silent zone alarm/restore: ... → INST SILENT EV→ OK → ENABLE → OK
System started: ... → SYSTEM STARTED EV → OK → ENABLE → OK
Fire alarm/restore: ... → FIRE ALM/REST EV → OK → ENABLE → OK
24-Hour zone alarm/restore: ... → 24H ALM/REST EVENT→ OK → ENABLE → OK
Low battery: ... → LOW BATTE RY EVENT → OK → ENABLE → OK
Temperature risen: ... → TEMP HIGH EVENT → OK → ENABLE → OK
Temperature fallen: ... → TEMP LOW EVENT → OK → ENABLE → OK
Wireless signal loss/restore: ... → WLESS SIGN L/R EV → OK → ENABLE → OK
Disarmed by user (Duress code): OK → iiii → OK → MS SETTINGS → OK → DATA MESSAGES 2 →
OK → DISARM DURESS EV → OK → ENABLE → OK
SGS code entered: ... → ARM/DARM SGS EVENT → OK → ENABLE → OK
Armed by user (partial arm): ... → ARM PARTIAL EV → OK → ENABLE → OK
Siren fail/restore: ... → SIREN FAIL/REST EV → OK → ENABLE → OK
RF jammer detected/RF jamming stopped: ... → RF JAMMER DETECTED → OK → ENABLE → OK
Date/time not set: ... → DATE/ TIME NOT SET → OK → ENABLE → OK
GSM connection failed: ... → GSM CONNECT FAILED → OK → ENABLE → OK
GSM/GPRS antenna fail/restore: ... → GSM ANT FAIL/REST → OK → ENABLE → OK
System shutdown: ... → SYSTEM SHUTDOWN EV → OK → ENABLE → OK
Communication bus fail/restore: ... → COMM BUS FAIL/RST → OK → ENABLE → OK
IP connection failed: ... → GPRS CONNECT FAIL → OK → ENABLE → OK
Zone bypassed/activated: ... → ZONE BYPASS → OK → ENABLE → OK
CO sensor lifetime exceeded: ... → CO SENS LFTIME EXC→ OK → ENABLE → OK
CO level critical: ... → CO LEVEL CRITICAL → OK → ENABLE → OK
Report/Control zone triggered/restored: ... → REPORT → OK → ENABLE → OK
Armed/disarmed in STAY mode: OK → iiii → OK → MS SETTINGS → OK → DATA MESSAGES 3 →
OK→ ARM/DARM STAY EV → OK → ENABLE → OK
Conguration via remote connection started: ... → CFG VIA REMOTE EV → OK → ENABLE → OK
Panic/Silent zone alarm/restore: ... → PA/SIL ALM/REST EV → OK → ENABLE → OK
Value: iiii – 4-digit installer code.