143
143
EN
ESIM384 Installation and Conguration Manual v1.1
Enable data message
EKB2
Menu path:
Burglary alarm/restore: OK iiii OK MS SETTINGS OK DATA MESSAGES 1 OK
BURGLR ALM/REST EV OK ENABLE OK
Mains power loss/restore: ... MAIN POWER L/R EV OK ENABLE OK
Armed/disarmed by user: ... ARM/DISARM EVENT OK ENABLE OK
Battery failed: ... BATTERY FAILED OK ENABLE OK
Battery dead or missing/battery connection restore: ... BATTERY DEAD/MISS OK
ENABLE OK
Test event: ... TEST EVENT OK ENABLE OK
Tamper alarm/restore: ... TAMPER ALM/REST EV OK ENABLE OK
Instant Silent zone alarm/restore: ... INST SILENT EV OK ENABLE OK
System started: ... SYSTEM STARTED EV OK ENABLE OK
Fire alarm/restore: ... FIRE ALM/REST EV OK ENABLE OK
24-Hour zone alarm/restore: ... 24H ALM/REST EVENT OK ENABLE OK
Low battery: ... LOW BATTE RY EVENT OK ENABLE OK
Temperature risen: ... TEMP HIGH EVENT OK ENABLE OK
Temperature fallen: ... TEMP LOW EVENT OK ENABLE OK
Wireless signal loss/restore: ... WLESS SIGN L/R EV OK ENABLE OK
Disarmed by user (Duress code): OK iiii OK MS SETTINGS OK DATA MESSAGES 2
OK DISARM DURESS EV OK ENABLE OK
SGS code entered: ... ARM/DARM SGS EVENT OK ENABLE OK
Armed by user (partial arm): ... ARM PARTIAL EV OK ENABLE OK
Siren fail/restore: ... SIREN FAIL/REST EV OK ENABLE OK
RF jammer detected/RF jamming stopped: ... RF JAMMER DETECTED OK ENABLE OK
Date/time not set: ... DATE/ TIME NOT SET OK ENABLE OK
GSM connection failed: ... GSM CONNECT FAILED OK ENABLE OK
GSM/GPRS antenna fail/restore: ... GSM ANT FAIL/REST OK ENABLE OK
System shutdown: ... SYSTEM SHUTDOWN EV OK ENABLE OK
Communication bus fail/restore: ... COMM BUS FAIL/RST OK ENABLE OK
IP connection failed: ... GPRS CONNECT FAIL OK ENABLE OK
Zone bypassed/activated: ... ZONE BYPASS OK ENABLE OK
CO sensor lifetime exceeded: ... CO SENS LFTIME EXC OK ENABLE OK
CO level critical: ... CO LEVEL CRITICAL OK ENABLE OK
Report/Control zone triggered/restored: ... REPORT OK ENABLE OK
Armed/disarmed in STAY mode: OK iiii OK MS SETTINGS OK DATA MESSAGES 3
OK ARM/DARM STAY EV OK ENABLE OK
Conguration via remote connection started: ... CFG VIA REMOTE EV OK ENABLE OK
Panic/Silent zone alarm/restore: ... PA/SIL ALM/REST EV OK ENABLE OK
Value: iiii – 4-digit installer code.

Table of Contents