108
MEDEA Programming Manual
The following buttons appear under the table:
Update: This can be used to update the list.
CSV: This can be used to export the events list to a .csv file, which can be opened with a
spreadsheet.
PDF: This can be used to export the events list to a PDF file.
The < and > buttons in the bottom right are used to navigate between table pages.
6.1.10 Testing procedure
Before handing a system over to the customer, test is using the DIAGNOSTIC submenu:
1. Activate the entire system.
2. Trigger all detectors simulating intrusion attempts and check that all detectors have stored the alarm.
3. Deactivate the entire system.
4. Test the various outputs by activating them manually and check that the associated devices operate
as designed.
5. Test the various scenarios by activating them manually and check that the end result is as expected.
6. Test the various sectors one by one, activating them and verifying that the associated detectors
operate as designed.
7. Try out the various contacts and check that the expected alerts are successful.
If any of the previous tests fail, check the devices involved and the programming and repeat the test.
7 - UTILITY
7.1 UTILITY Menu
The UTILITY menu can be used to save the programming of the system and reload it in the control panel.
Importantly the control panels must be of the same size.
EXPORT can be used to export the programming.
IMPORT can be used to import in the control panel a previously saved programming.
8 - Keypad menu
8.1 Accessing the Installer menu
IMPORTANT! The Installer must have been enabled by the Master to access the menu. Proceed
as follows to enable the Installer, if necessary:
1. Enter the Master code on the keypad (default 111111) and press MENU.
2. Press the button until "UT01: MASTER ENABLE" appears.
3. "ENABLE INSTALLAER" will appear. Press OK.
4. Press the button until "CODE ON" is displayed.
5. Press the ESC button until "EXIT MENU? OK=YES ESC=NO” appears.
6. Press the OK button twice to save the change.
To access the Installer menu, enter the Installer code on the keypad (default: 000000) and press the MENU
button. This opens the main menu (page 110) from which you can access all the submenus for
programming the system.
Similarly, enter the Master (or Technical Manager or User) code instead of the Installer code to access the
Master (or Technical Manager or User) menus.