8.8 Alarms Memory menu
This shows the stored intrusion alarms, from the most recent to the oldest.
Available for Master, User, Installer.
It is accessed through the Main menu → MEM ALARM menu.
Use the ▼ and ▲ buttons to scroll through the various stored alarms.
Each alarm event is displayed with a sequential number, the time and date it occurred (hh:mm and dd/mm)
and an abbreviated description (Short descr.).
Press the OK button to open the submenu to display the details of the alarm. Use the ▼ and ▲ buttons
to scroll through the various submenu screens.
The first screen shows the complete description of the alarm (Long descr.), the physical address of the
input (d.in, where d is the device with UC = control panel, EP = expansion module, KP = keypad, DK =
key reader, and in is the identification in the device) and the custom description (Label).
The second indicates the concerned sector.
The third screen shows the input type and the physical address d.in again.
Press the ESC button to go back to the alarm list.
You can clear the entire alarm list by pressing the OK button when "DELETE MEMORY?" message
appears on the display.