57
Reference Manual
00809-0100-2460, Rev DE
Configuration
October 2018
Configuration
How to check Communication Channel and Port
To check which channels are enabled:
a. In the WinSetup workspace open the Protocols folder.
b. Expand the master protocol folder (ModbusMaster in this example).
c. Check that the desired channel is enabled. In the example above the Modbus Master Channel 1 is
enabled. Disabled channels do not appear in the protocol folder.
To check which communication port that is associated with a certain channel:
a. Right-click the desired protocol channel icon and choose Properties.
b. Open the Communication tab and check which communication port that is selected. This
example shows that port COM1 is used for Protocol Channel 1.
See the Rosemount Tank Gauging System Configuration Manual
(Document no. 00809-0300-5100) for
more information on how to configure communication protocols.
Modbus Master protocol folder
Modbus Master channel 1
Protocols folder
Communication
port on the
TankMaster PC