3 Transducer Blocks (transmission blocks) PROline Prosonic Flow 93 FOUNDATION Fieldbus
116 Endress+Hauser
Pipe Data -
Pipe Standard
AUTO - OOS For selecting the standard pipe.
Options:
OTHERS
DIN PN10
DIN PN16
DIN 28610
DIN 28614
DIN 28615
DIN 28619
ANSI SCHEDULE 40
ANSI SCHEDULE 80
AWWA CLASS 50
AWWA CLASS 53
AWWA CLASS 55
Factory setting:
DIN PN10
Pipe Data -
Nominal
Diameter
AUTO - OOS For selecting the nominal diameter of the pipe.
Options:
OTHERS
DN 25/1IN
DN 40/1½IN
DN 50/2IN
DN 80/3IN
DN 100/4IN
DN 150/6IN
DN 200/8IN
DN 250/10IN
DN 300/12IN
DN 400/16IN
DN 450/18IN
DN 500/20IN
DN 600/24IN
DN 700/28IN
DN 750/30IN
DN 800/32IN
DN 900/36IN
DN 1000/40IN
DN 1200/48IN
DN 1400/54IN
DN 1500/60IN
DN 1600/64IN
DN 1800/72IN
DN 2000/80IN
Factory setting:
DN 80/3IN
Pipe Data -
Unit Nominal
Diameter
read only Displays the unit used in the Pipe Data - Nominal Diameter unit.
Note!
The unit is selected in the System Unit - Length parameter, see
Page 112.
TRANSDUCER_CH1 and TRANSDUCER_CH2 (E+H parameters) /
Base index 1200 and 1300
Parameter Write access
with operating
mode
(MODE_BLK)
Description