PROline Prosonic Flow 93 FOUNDATION Fieldbus 3 Transducer Blocks (transmission blocks)
Endress+Hauser 117
Pipe Data -
Pipe Material
AUTO - OOS For selecting the pipe material.
Options:
CARBON STEEL
DUCTILE IRON
STAINLESS STEEL
SS ANSI 304
SS ANSI 316
SS ANSI 347
SS ANSI 410
SS ANSI 430
HASTELLOY C
PVC
PE
LDPE
HDPE
GRP
PVDF
PA
PP
PTFE
GLASS PYREX
ASBESTOS CEMENT
OTHERS
Factory setting:
STAINLESS STEEL
Pipe Data -
Reference Value
AUTO - OOS
Note!
This parameter is not active unless “Sound Vel. Pipe” was
selected in the “Sensor Param. - Measurement” parameter, (see
Page 122).
Entry of the thickness of the reference component (e.g. flange)
which serves as the basis for measuring the sound velocity of the
pipes, (see Page 118).
User input:
5-digit floating-point number
Factory setting:
5 (mm)
Note!
The unit used is displayed in the “Pipe Data - Unit Reference
Value” parameter.
Pipe Data -
Unit Reference
Value
read only Displays the unit for the thickness of the reference component.
Note!
The unit is selected in the “System Unit - Length” parameter, see
Page 112.
“TRANSDUCER_CH1” and “TRANSDUCER_CH2” (E+H parameters) /
Base index 1200 and 1300
Parameter Write access
with operating
mode
(MODE_BLK)
Description