Proline Prosonic Flow W 400 HART Operation
Endress+Hauser 127
Parameter Prerequisite Description Selection / User entry /
User interface
Logging interval The Extended HistoROM application
package is available.
Define the logging interval for data
logging. This value defines the time
interval between the individual data
points in the memory.
0.1 to 3 600.0 s
Clear logging data The Extended HistoROM application
package is available.
Clear the entire logging data. • Cancel
• Clear data
Data logging – Select the type of data logging. • Overwriting
• Not overwriting
Logging delay In the Data logging parameter, the Not
overwriting option is selected.
Enter the time delay for measured
value logging.
0 to 999 h
Data logging control In the Data logging parameter, the Not
overwriting option is selected.
Start and stop measured value logging. • None
• Delete + start
• Stop
Data logging status In the Data logging parameter, the Not
overwriting option is selected.
Displays the measured value logging
status.
• Done
• Delay active
• Active
• Stopped
Entire logging duration In the Data logging parameter, the Not
overwriting option is selected.
Displays the total logging duration. Positive floating-point
number
* Visibility depends on order options or device settings