Proline Prosonic Flow W 400 HART Technical data
Endress+Hauser 165
DN 50 to 4000 (2 to 160"):
Sensor cable, TPE halogen-free
Cable sheath: TPE halogen-free
Cable plug: nickel-plated brass
Sensor cable PTFE
Cable sheath: PTFE
Cable plug: stainless steel 1.4301 (304), 1.4404 (316L)
Ultrasonic transducer
Holder: stainless steel 1.4301 (304), 1.4404 (316L)
Housing: stainless steel 1.4301 (304), 1.4404 (316L)
Strapping bands/bracket: stainless steel 1.4301 (304), 1.4404 (316L)
Contact surfaces: chemically stable plastic
Coupling pads
–40 to +100 °C (–40 to +212 °F): silicon-based thermal pad H48.2 (0.5 mm (0.02 in))
+80 to +170 °C (+176 to +338 °F): VMQ-silicone-rubber (vinyl methyl silicone)
(0.5 mm (0.02 in))
Coupling paste
Coupling grease
Accessories
External WLAN antenna
Antenna: ASA plastic (acrylonitrile styrene acrylate) and nickel-plated brass
Adapter: Stainless steel and nickel-plated brass
Cable: Polyethylene
Plug: Nickel-plated brass
Angle bracket: Stainless steel
Process connections Flanges:
ASME B16.5
For information on the different materials used in the process connections →  164
16.11 Display and user interface
Languages Can be operated in the following languages:
Via local operation:
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish,
Chinese, Japanese, Bahasa (Indonesian), Vietnamese, Czech, Swedish
Via "FieldCare", "DeviceCare" operating tool:
English, German, French, Spanish, Italian, Chinese, Japanese
Via Web browser
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish,
Chinese, Japanese, Bahasa (Indonesian), Vietnamese, Czech, Swedish