Proline Prowirl R 200 HART Technical data
Endress+Hauser 203
The following types of monitoring in safety equipment are possible:
Volume flow
Functional Safety Manual with information on the SIL device → 205
Pressure Equipment
Directive
• With the identification PED/G1/x (x = category) on the sensor nameplate,
Endress+Hauser confirms conformity with the "Essential Safety Requirements" specified
in Appendix I of the Pressure Equipment Directive 2014/68/EC.
• Devices not bearing this marking (PED) are designed and manufactured according to
good engineering practice. They meet the requirements of Art. 4, Par. 3 of the Pressure
Equipment Directive 2014/68/EU. The range of application is indicated in tables 6 to 9
in Annex II of the Pressure Equipment Directive 2014/68/EC.
Experience The Prowirl 200 measuring system is the official successor to Prowirl 72 and Prowirl 73.
Other standards and
guidelines
• EN 60529
Degrees of protection provided by enclosures (IP code)
• DIN ISO 13359
Measurement of conductive liquid flow in closed conduits - Flanged-type
electromagnetic flowmeters - Overall length
• EN 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory
use - general requirements
• IEC/EN 61326
Emission in accordance with Class A requirements. Electromagnetic compatibility (EMC
requirements).
• NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control
equipment
• NAMUR NE 32
Data retention in the event of a power failure in field and control instruments with
microprocessors
• NAMUR NE 43
Standardization of the signal level for the breakdown information of digital transmitters
with analog output signal.
• NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics
• NAMUR NE 105
Specifications for integrating fieldbus devices in engineering tools for field devices
• NAMUR NE 107
Self-monitoring and diagnosis of field devices
• NAMUR NE 131
Requirements for field devices for standard applications
16.13 Application packages
Many different application packages are available to enhance the functionality of the
device. Such packages might be needed to address safety aspects or specific application
requirements.
The application packages can be ordered with the device or subsequently from
Endress+Hauser. Detailed information on the order code in question is available from your
local Endress+Hauser sales center or on the product page of the Endress+Hauser website:
www.endress.com.
Detailed information on the application packages:
Special Documentation for the device