C8 Maintenance    3. Covers 
 
C Series Maintenance Manual Rev.2  219 
C8-A701** (C8), C8-A901** (C8L) 
 
   
Install the connector plate to the Manipulator.
 
Hexagon socket head cap bolts: 11-M4×10 
Tightening Torque: 4.0 ± 0.2 N·m 
 
Be careful not to get the cables caught between the cover and the Manipulator. 
 
C8-A701** (C8), C8-A901** (C8L) 
 
 
  Install the spacers to the holes on the gasket. 
(11 places) 
  Apply the liquid gasket to the base rear gasket. 
Install the base rear gasket to the connector plate. 
(See the figure for gasket applying points) 
Gasket 
Applying 
point (×11) 
 
After applying the liquid gasket, leave the gasket until the liquid gasket becomes solid 
and the gasket is fixed. 
  Install the connector plate to the Manipulator. 
Hexagon socket head cap bolts: 11-M4×10 
Tightening torque: 4.0 ± 0.2 N·m 
Be careful not to get the gasket and cables caught between the cover and the 
Manipulator. 
Replace the gasket if there are flaws or deteriorations.