C8 Maintenance 13. Replacing the LED Lamp
C Series Maintenance Manual Rev.2 403
13. Replacing the LED Lamp
WARNING
Do not connect or disconnect the motor connectors while the power to the robot
system is turned ON. Connecting or disconnecting the motor connectors
with
the power ON is extremely hazardous and may result
in serious bodily injury as
the Manipulator may move abnormally, and also may result in
electric shock
and/or malfunction of the robot system.
To shut off power to the robot system, disconnect the power plug from the power
source. Be sure to connect the AC power cable to a power receptacle.
DO NOT connect it directly to a factory power source.
Before
performing any replacement procedure, turn OFF the Controller and
related equipment,
and then disconnect the power plug from the power source.
Performing any replacement procedure with the power ON is extremely hazardous
and may result in
electric shock and/or malfunction of the robot system.
LED lamp
(Figure: C8-A1401** (C8XL))
For Protection model, please contact the supplier of your region.
Name Qty. Note
Maintenance Parts LED lamp 1
1668127
(Standard, Clean-room models)
Tools
Cross-point screwdriver (#2)
1
For cross recessed head screws