C8 Maintenance 4. Cable Unit
C Series Maintenance Manual Rev.2 247
Connect the connector to the control board 2.
Connector: GS02
Connect the cable connectors inside the Arm #3.
Connectors: X141, X151, X161, BR041, BR051, X041, X71, X72, PS, LED, BT51, BT4
(Hold the clip to remove.)
Install the two ground wire terminals to the Arm #3.
Green/yellow: Left side Green: Right side
Cross recessed head screws with washer: 2-M4×8
Tightening torque: 0.9 ± 0.1 N·m
Use air tube fittings (elbows) to connect air tubes of the same color.
Remove the air tube fittings from the old cables to use them again.
Adjust the connector protrusion so that the cover can be installed.