EasyManua.ls Logo

Epson C Series - Page 392

Epson C Series
668 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C8 Maintenance 9. Joint #5
372 C Series Maintenance Manual Rev.2
When using the belt tension tensile jig (maintenance part):
Fix the belt tension tensile jig (for J4, J5, and J6) with the screws
(2-M4×15) and push the rubber against the pulley.
Tension is applied as the set screw (M6×15
) is pushed by the
rubber.
7. Install the air tube fitting in the front of the Joint #5 motor unit.
After tightening by hand, tighten one sixth to quarter of a turn.
Tightening of the fitting:
Fitting is too tight:
It may cause air leakage due to screw breakage or gasket
deformation.
Fitting is too loose:
It may cause loose screws and air leakage.
8. Connect the following connectors.
Connectors: X052, X152, BT52, BR052
9. Install the brake power supply to the plate.
Cross recessed head screw with captive washer: 2-M3×6
Tightening torque: 0.45 ± 0.1 N·m
10. Fix the cable protection bracket to the Arm #4.
Hexagon socket head cap bolts: 2-M4×10
Tightening torque: 4.0 ± 0.2 N·m
Be careful not to get the cables caught. It may result in cable
breakage.
11. Install the Arm #4 side cover.
For details, refer to C8 Maintenance: 3. Covers.
12. Perform the calibration.
For details, refer to C8 Maintenance: 16. Calibration.
NOTE
NOTE

Table of Contents

Related product manuals