C4 Maintenance 4. Cable Unit
38 C Series Maintenance Manual Rev.2
Install the air tubes to the user plate fittings.
Air tube projection length: 45 mm
Install the user plate to the Arm #4.
Hexagon socket head cap bolt: 2-M3×6
Fix the Joint #5 motor unit to the Arm #4 temporarily and place the
Joint #5 timing belt on the pulleys.
Hexagon socket head cap bolts: 2-M4×15 (with a plain washer)
Fix the Joint #6 motor unit to the Arm #4 temporarily and place the
Joint #5 timing belt on the pulleys.
Hexagon socket head cap bolts: 2-M4×15 (with a plain washer)