Maintenance 9. Troubleshooting
274 RC700 / RC700-A Rev.23
No. Message Remedy Note 1 Note 2
7030
Specified point label is beyond the
maximum length. Specify a valid
point label.
Change the point label.
7031
Description for the specified point
is beyond the maximum length.
Specify a valid description.
Change the comment.
7032
Point file is corrupted. Check sum
error.
Create the point file again.
7033
Specified point file cannot be
found. Specify a valid point file
name.
Check the name of the specified point
file.
7034 Cannot save the point file.
Failed to save the point file (create a
temporary file).
Reboot the controller.
Initialize the controller firmware.
Replace the controller.
7035 Cannot save the point file.
Failed to save the point file (file
open).
Reboot the controller.
Initialize the controller firmware.
Replace the controller.
7036 Cannot save the point file.
Failed to save the point file (renew
the file header).
Reboot the controller.
Initialize the controller firmware.
Replace the controller.
7037 Cannot save the point file.
Failed to save the point file (create
the file name).
Reboot the controller.
Initialize the controller firmware.
Replace the controller.
7038 Cannot save the point file.
Failed to save the point file (copy the
file).
Reboot the controller.
Initialize the controller firmware.
Replace the controller.
7039 Cannot save the point file.
Failed to save the point file (change
the file name).
Reboot the controller.
Initialize the controller firmware.
Replace the controller.
7040
The point label is not correct.
Specify a valid point label.
The initial character of the point label
name is improper. Correct the label
name.
7041
The point label is not correct.
Specify a valid point label.
Inadequate character is used.
Correct the label name.
7042 The pallet cannot be defined.
Undefined flag for pallet data is
mixed.
Check the point data.
Correct the point data.
7043 Invalid point file version.
The point file version is different.
Re-create the point file.
7044
The point file format version is
unsupported.
The point file is not supported.
Re-create the point file.
7045
The specified work queue number
is invalid.
Check the specified work queue
number.