Maintenance 9. Troubleshooting
RC700 / RC700-A Rev.23 275
7046 The specified work queue is full.
The work queue is full. Delete the
point data from the work queue and
7047
The specified work queue data
Check the specified index.
7048
The work queue is not correctly
initialized.
Failed to initialize the work queue
(allocate memory).
Reboot the controller.
Initialize the controller firmware.
7049
The parameter of the work queue
instruction is invalid.
Check the parameters of the
commands related to the work
7050
Cannot execute while work queue
data is registered.
Cannot set the work queue since the
point data is registered to the work
queue.
Empty the work queue before setting.
7101
Fieldbus slave. An error occurred
during I/O data transform.
The fieldbus slave board is broken or
the controller software is damaged.
Restore the controller firmware.
2
3
4
10
A communication data error was
detected during communication.
The communication cable has a
problem. Check the communication
cable and its related units.
11
12
The fieldbus is broken or the
controller software is damaged.
Restore the controller firmware.
14
The PLC is not running or not
connected.
Check the PLC, the communication
cable, and peripherals.
(If Code 1 is 22 when the CC-Link
22