Maintenance 9. Troubleshooting
276 RC700 / RC700-A Rev.23
No. Message Remedy Note 1 Note 2
7103
Fieldbus slave. Timeout error
occurred during I/O data transform.
The fieldbus slave board is broken or
the controller software is damaged.
Restore the controller firmware.
2
3
A communication data error was
detected during communication.
The communication cable has a
problem. Check the communication
cable and its related units.
4
7150
Fieldbus master.
Check the connection of the
communication cable for the fieldbus.
7151 Fieldbus master. Bus power is off.
Check whether the communication
cable for the fieldbus is powered.
7152
Fieldbus master.
Bus status error.
Check the fieldbus master board.
Replace the fieldbus master board.
There is not enough memory.
The specified path is invalid.
Make sure the specified path exists.
The specified path already exists.
If the specified directory or file
already exists, you cannot execute.
The file specified by path does not
Make sure the specified file exists.
File size is too large.
Specify the file that is less than 2G
The specified file is open.
The specified file number is already
existing. Use another file number.
The open mode is illegal.
Make sure you opened in reading or
writing mode.
Make sure there are data to read.
The specified connection is open.
The specified file number is already
existing. Use another file number.
A connection-level error occurred
while opening the connection.
Check the access right of database.
The connection is closed.
Use OpenDB and open the database.
An unsupported data type was
Convert the data into string or
Data size is too large.
Too large data in a line. Specify the
query so that necessary field are only
The specified file type is not
supported.
Check the type of Excel file.
There is no selected data.
Make sure the data you retrieved
exists.
No bytes were available to read.
There are no retrieved data. Check
The port is in an invalid state.
Check the device setting for the
The specified port is open.
Check the port number to open.
Check the port number to close.
The specified port is not open.
Check the port number to open.
Timeout reading from the port.
Check the port timeout period and
update to the appropriate setting.