DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 150
Confidential
10. Holding the shaft from under, remove the screw and the shaft.
A) Silver, Hexagon socket M3x8: four pieces
11. Pressing the bearing down and remove the CR LOCK SOLENOID.
Figure 4-119. Removing the CR LOCK SOLENOID
C A U T I O N
In the next step, the shaft will drop unless holding it from under the
shaft when removing the screw.
When routing the cable, make sure to give it one turn around
the marked clamp. See Figure 4-115.
Make sure the bearing is correctly lubricated and moves
smoothly before reassembling. See p253 for Lubrication
details.
A
As seen from the front
CR LOCK SOLENOID
Shaft
Bearing
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5 “Adjustment” (see p184) and perform
specified adjustments after replacing or removing this part.
<Adjustment item>
1. Solenoid Test