Epson Stylus Pro GS6000 Revision F
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 151
Confidential
4.4.9.5 CR MOTOR
1. Remove the TOP COVER (right only). (p85)
2. Remove the SIDE COVER (right only). (p89)
3. Remove the IH COVER (right only). (p90)
4. Disconnect the two terminals.
5. Remove the four screws using a hex wrench.
A) Silver, Hexagon socket M4x8: four pieces
6. Detach the CR REDUCTION BELT from the pinion, and remove the CR MOTOR
while drawing the pinion gear from the hole.
Figure 4-120. Removing the CR MOTOR
So as not to confuse the terminals of the CR Motor cable with each
other, make sure to mark them in some way before disconnecting
them so that you can plug them back correctly.
Be sure to refer to Chapter 5 “Adjustment” (see p184) and perform
specified adjustments after replacing or removing the CR MOTOR.
<Adjustment items>
1. CR Belt Tension Adjustment
2. CR Reduction Belt Tension Adjustment
3. CR Motor Counter Reset
4. Head Uni-D/Bi-D Low Gap Adjustment
5. Media Side Margin Adjustment