4.4.11.7 PUMP ASSY
1. Unlock the Carriage and move it to the center. (p83)
2. Remove the MAINTENANCE COVER ASSY (right only). (p91)
3. Remove the MAINTE COVER, B (right only). (p92)
4. Remove the four screws and remove the fixing plate. (Step 4 in 4.4.11.3
MAINTENANCE ASSY). (p163)
5. Disconnect two each tubes ((1) to (4)) from each PUMP ASSY.
6. Disconnect the two relay connectors.
Figure 4-144. Disconnecting the tubes and relay connectors
In the next step, the waste ink in the tubes will come out. Therefore
make sure to place something like tissue paper to absorb the ink.
Before disconnecting the relay connectors, mark them in some way
to distinguish them when reassembling.