4.4.11.9 SUB TANK ASSY
1. Discharge ink using the service program. (p210)
2. Remove the TOP COVER (L or R). (p85)
3. Remove the PANEL COVER, T (p86) or the MAINTE COVER T (p88).
4. Remove the SIDE COVER (L or R). (p89)
5. Remove the IH COVER (L or R). (p90)
6. Remove the TWO WAY VALVE ASSY. (p170)
7. Remove the SUB TANK SENSOR. (p131)
8. Disconnect the connector for the solenoid.
9. Release the cables from the 3 clamps.
Figure 4-149. Releasing the cable
10. Disconnect the front and rear tubes from the SUB TANK ASSY.
Figure 4-150. Removing the SUB TANK ASSY
Clamps
Connector of the solenoid
The tube connectors include “O-RINGs” (black rubber rings). To
prevent any leak, those O-RINGs have to be replaced with new
ones if the connectors are once opened.
C H E C K
P O I N T
Detach the assy one by one to the target assy from the outside to the
inside.
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5 “Adjustment” (see p184) and perform
specified adjustments after replacing or removing this part.
<Adjustment item>
1. Sensor Test
Tube