5-22
Sub-assembly I
Assembly
Step
Assembly ProcedurePart Name
19
20
(21)
22
Insulation sheet
Earth plate-Print head
(FFC-Print head)
Print head unit
CPP-tite (M3 x 10) x 1
Paste the Insulation sheet to the Earth plate-Print head.
Place the Earth plate-Print head on the Carriage assembly. (The
plate is not fastened here. It is fastened in
Main Assembly 16
.)
Attach the FFC-Print head to the print head unit connector.
Attach the Print head unit to the Carriage assembly and tighten the
screw provisionally. (Final tightening is done in the platen gap
adjustment performed in
Main Assembly 16
.
<Checkpoint>
Make sure that the left and right sides of the Insulation sheet are not
protruded from the Earth plate-Print head.
CONFIDENTIAL