SMP 300 Series • Remote Communication and Control 120
Command Function SIS Command
(Host to Device)
Response
(Device to Host)
Additional Description
IP Setup Commands (continued)
Set current port timeout E
0
*
X6(
TC
}
Pti 0
*
X6(
]
View current port
timeout
E
0 TC
} X6(
]
Set global IP port
timeout
E
1*
X6(
TC
}
Pti1
*
X6(
]
View global IP port
timeout
E
1
TC
} X6(
]
KEY:
X6(
= Port timeout In tens of seconds, zero padded 1 to 65000 (default: 00030 = 300 seconds)
RS-232 Port
Configure serial port
parameters
E
1*
X2%
,
X2^
,
X2&
,
X2*
CP
}
Cpn
01Ccp
X2%
,
X2^
,
X2&
,
X2*]
Reset serial port E
1*9600,n,8,1CP
}
Cpn
01Ccp
X2%
,
X2^
,
X2&
,
X2*]
View serial port settings E
1CP
} X2%
,
X2^
,
X2&
,
X2*
]
Set serial port receive
timeout
E
1*
X1(
*
X2)
*
X2@
*
X2!
CE
}
Cpn01
Cce
X1(
,
X2)
,
X2@
,
X2!
]
View serial port receive
timeout
E
1CE
} X1(
,
X2)
,
X2@
,
X2!
]
KEY:
X1(
= Port timeout Time in tens of milliseconds to wait for characters coming into a serial port before terminating
(min=0, max=32767, default: 10 = 100 ms). The response is returned with leading zeros.
X2)
= Intercharacter timeout Time in tens of milliseconds to wait between characters coming into a serial port before terminating
(min=0, max=32767. Default: 2 = 20 ms). The response is returned with leading zeros. Commands using
both
X1(
and
X2)
must have both values = 0 or both set to non‑zero.
X2!
= Primary port status Parameter to set either the Length of message to receive, or the Delimiter value.
L=#=byte count (min=0, max=32767. Default=0L=0 byte count).
D = decimal value for ASCII character. (min=0, max=00255. Default=00000L).
Value is placed prior to parameter: 3 byte length = “3L” and ASCII 0A delimiter is “10D”. The parameter is
case sensitive, must use capital D or capital L. The response is returned with leading zeros.
X2@
= Length delimiter Priority status for receiving timeouts: 0 = Use Send data string command parameters when available,
1 = Use Configure receive timeout command parameters (default = 0).
X2%
= RS‑232 baud rate 9600 (default), 19200, 38400, 57600, 115200 baud
X2^
= RS‑232 parity Odd, Even, None (default), Mark, Space
X2&
= RS‑232 data bits 7, 8 (default)
X2*
= RS‑232 stop bits 1 (default), 2
Front Panel Lock (Executive Mode)
Set Executive mode X5!
X Exe
X5!]
View Executive mode
X
X5!]
KEY:
X5!
= Executive mode 0 = Off, 1 = Complete lockout (no front panel control), 2 = Menu lockout, 3 = Allow recording controls only
RCP 101 Executive Mode
Executive mode on
99
*
1X Exe99*1
]
Executive mode off
99
*
0X Exe99
*0
]
Query status
99
*
X
X( ]
KEY:
X(
= On/off 0 = Disabled/off (default), 1 = Enabled/on

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics SMP 300 Series and is the answer not in the manual?

Extron electronics SMP 300 Series Specifications

General IconGeneral
BrandExtron electronics
ModelSMP 300 Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals