SMP 300 Series • Remote Communication and Control 120
Command Function SIS Command
(Host to Device)
Response
(Device to Host)
Additional Description
IP Setup Commands (continued)
Set current port timeout E
0
*
X6(
TC
}
Pti 0
*
X6(
]
View current port
timeout
E
0 TC
} X6(
]
Set global IP port
timeout
E
1*
X6(
TC
}
Pti1
*
X6(
]
View global IP port
timeout
E
1
TC
} X6(
]
KEY:
X6(
= Port timeout In tens of seconds, zero padded 1 to 65000 (default: 00030 = 300 seconds)
RS-232 Port
Configure serial port
parameters
E
1*
X2%
,
X2^
,
X2&
,
X2*
CP
}
Cpn
01•Ccp
X2%
,
X2^
,
X2&
,
X2*]
Reset serial port E
1*9600,n,8,1CP
}
Cpn
01•Ccp
X2%
,
X2^
,
X2&
,
X2*]
View serial port settings E
1CP
} X2%
,
X2^
,
X2&
,
X2*
]
Set serial port receive
timeout
E
1*
X1(
*
X2)
*
X2@
*
X2!
CE
}
Cpn01
•
Cce
X1(
,
X2)
,
X2@
,
X2!
]
View serial port receive
timeout
E
1CE
} X1(
,
X2)
,
X2@
,
X2!
]
KEY:
X1(
= Port timeout Time in tens of milliseconds to wait for characters coming into a serial port before terminating
(min=0, max=32767, default: 10 = 100 ms). The response is returned with leading zeros.
X2)
= Intercharacter timeout Time in tens of milliseconds to wait between characters coming into a serial port before terminating
(min=0, max=32767. Default: 2 = 20 ms). The response is returned with leading zeros. Commands using
both
X1(
and
X2)
must have both values = 0 or both set to non‑zero.
X2!
= Primary port status Parameter to set either the Length of message to receive, or the Delimiter value.
L=#=byte count (min=0, max=32767. Default=0L=0 byte count).
D = decimal value for ASCII character. (min=0, max=00255. Default=00000L).
Value is placed prior to parameter: 3 byte length = “3L” and ASCII 0A delimiter is “10D”. The parameter is
case sensitive, must use capital D or capital L. The response is returned with leading zeros.
X2@
= Length delimiter Priority status for receiving timeouts: 0 = Use Send data string command parameters when available,
1 = Use Configure receive timeout command parameters (default = 0).
X2%
= RS‑232 baud rate 9600 (default), 19200, 38400, 57600, 115200 baud
X2^
= RS‑232 parity Odd, Even, None (default), Mark, Space
X2&
= RS‑232 data bits 7, 8 (default)
X2*
= RS‑232 stop bits 1 (default), 2
Front Panel Lock (Executive Mode)
Set Executive mode X5!
X Exe
X5!]
View Executive mode
X
X5!]
KEY:
X5!
= Executive mode 0 = Off, 1 = Complete lockout (no front panel control), 2 = Menu lockout, 3 = Allow recording controls only
RCP 101 Executive Mode
Executive mode on
99
*
1X Exe99*1
]
Executive mode off
99
*
0X Exe99
*0
]
Query status
99
*
X
X( ]
KEY:
X(
= On/off 0 = Disabled/off (default), 1 = Enabled/on