SMP 300 Series • Remote Communication and Control 121
Command Function SIS Command
(Host to Device)
Response
(Device to Host)
Additional Description
Password and Security Settings
Set administrator
password
E X3#
CA
}
Ipa
X3#]
View administrator
password
E
CA
}
****
] If no password is set, the
response is
]
(no ****).
Reset (clear)
administrator password
E
CA
}
Ipa
]
Set user password E X3#
CU
}
Ipu
X3#]
View user password E
CU
}
****
] If no password is set, the
response is
]
(no ****).
Reset (clear) user
password
E
CU
}
Ipu
]
View session security
level
E
CK
}
n
] Security level of connection
11 = User, 12 = Administrator
NOTE: The factory configured passwords for all accounts on this device have been set to the device serial number. In the event of a complete
system reset, the passwords convert to the default, which is no password.
KEY:
X3#
= Password Maximum length 128 characters. All alpha‑numeric characters permitted except |, and “space”.
File Commands
Change directory
E
path/directory/CJ
}
Dirl path/directory/
]
Return to root directory
E
/CJ
}
Dirl/
]
Up one directory E
..
CJ
}
Dirl path/directory/
]
View current directory E
CJ
}
path/directory/
]
Erase current directory
and included files
E
/EF
}
Ddl
]
Also deletes files inside directory
Erase current directory
and sub‑directories
E
//EF
}
Ddl
]
List files from current
directory and below
E
LF
}
path/filenamedate/timelength]
path/filenamedate/timelength]
path/filenamedate/timelength]
...
space_remainingBytes Left]]
filename/date/time/bytes left
NOTE: Folders and files in the /recordings/ folder are read‑only and cannot be deleted with /EF command. Recordings can be deleted with the
SIS command Delete Recording Event and Files by DB_ID.
SMP Recording Folder Shared on SMD
Enable folder share E
E1
*
1SHRF
}
ShrfE1*1
] Allow SMP Recording folder
share.
Disable folder share E
E1
*
0SHRF
}
ShrfE1
*0
] Disable SMP Recording folder
share.
Query folder share
setting
E
E1SHRF
} X( ] View folder share status.
Query path
E
P1SHRF
}
Verbose mode 2/3
<SMP IP>:/var/uf/recordings
]
ShrfP1*<SMP IP>:/var/uf/recordings
]
KEY:
X(
= Disable/enable 0 = Disabled (default), 1 = Enabled
Delete Recording Event and Files by DB_ID
Delete recording event
and file
E
Z
X59@
RCDR
}
RcdrZ
X59@]
KEY:
X59@
= Delete recording by DB_ID Valid DB_ID number (integer)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics SMP 300 Series and is the answer not in the manual?

Extron electronics SMP 300 Series Specifications

General IconGeneral
BrandExtron electronics
ModelSMP 300 Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals