SMP 300 Series • Remote Communication and Control 124
Command Function SIS Command
(Host to Device)
Response
(Device to Host)
Additional Description
View all recording events
View all events E
L RCDR
}
Example
Example
{"db_id":
,"start":, "identifier":"","creator":"",
"title":"", "state":, "media_present":"", "package":""}
]
{"db_id": 22, "start": 1582141003, "identifier":
"SMP300DHP-IP207_20200219-193643Z", "creator": "",
"title": "", "state": 11, "media_present": "true",
"package":"/var/internal/SMP300DHP-IP207_20200219-
193643Z"}
]
{"db_id":1,"start":1630344031,"identifier":"","creator":""
,"title":"","state":11,"media_present":1,"package":"/var/
internal/Adhoc_20210830-172034Z"}
}
{"db_id":2,"start":1630344858,"identifier":"","creator":"
","title":"","state":4,"media_present":1,"package":"/var/
internal/Adhoc_20210830-173420Z"}
]
KEY: "State" 0 = SCHEDULE_PENDING ‑ Recording Scheduled, 1 = SCHEDULE_CURRENT ‑ Recording Now
2 = SCHEDULE_PROCESSED ‑ Recording Finalized, 3 = SCHEDULE_FINISHED ‑ Ready to Upload
4 = SCHEDULE_ARCHIVING ‑ Uploading to Server,
5 = SCHEDULE_ARCHIVED ‑ Uploading to Server Complete,
6 = SCHEDULE_ARCHIVE_FAILED ‑ Uploading to Server Failed (retry pending),
8 = SCHEDULE_PACKAGE_DELETED ‑ Recording Deleted (to recover disk space),
9 = SCHEDULE_RECORD_FAILED ‑ Recording Failed (package corrupted),
10 = SCHEDULE_ARCHIVE_NOMETHOD ‑ No Transfer Method Defined,
11 = SCHEDULE_RECORD_SKIPPED ‑ Transfer Skipped,
200 = SCHEDULE_PACKAGE_RESCHED ‑ Transfer Rescheduled (one time)
Metadata commands
Set output metadata E
M
X53*
*
X53(
RCDR
}
RcdrM
X53*
*
X53( ]
Example:
E
M2*ProfessorXRCDR
}
RcdrM2*ProfessorX
]
Query output metadata E
M
X53*
RCDR
} X53( ]
Example: E
M2
RCDR
}
ProfessorX
]
KEY:
X53*
= Metadata parameter 0 = Contributor, 1 = Coverage, 2 = Presenter, 3 = Date (view only), 4 = Description, 5 = Format,
6 = Identifier (view only), 7 = Language, 8 = Publisher, 9 = Relation, 10 = Rights, 11 = Source,
12 = Subject, 13 = Title, 14 = Type, 15 = System Name, 16 = Course
X53(
= Metadata value Up to 127 alpha‑numeric characters. All metadata values are cleared to be ready for the next data. Metadata
cannot be updated once the recording starts. New metadata is applied to the next recording.
Presets
User Presets
Recall user preset
1*
X50@
*
X53)
. 1Rpr
X50@
*
X53)]
Set channel
X50@
to preset
X53)
.
Save user preset
1*
X50@
*
X53)
, 1Spr
X50@
*
X53)]
Set user name
E
1*
X53)
,
X53!
PNAM
}
Pnam1*
X53)
,
X53!]
Set preset number
X53)
to
name
X53!
.
Query user name E
1*
X53)
PNAM
} X53!]
Query user presets
52*
X50!
#
Verbose mode 2/3
X(
1
X(
2
X(
3
...
X(
16
]
PreU
X50!
*
X(
1
X(
2
X(
3
...
X(
16
]
KEY:
X(
= On/off 0 = Disabled/unassigned/off/unmuted (default), 1 = Enabled/assigned/on/muted
X50!
= Input number 1 to 5
X50@
= Output channel 1 = Channel A, 2 = Channel B
X53)
= Preset Number 1 to 32
X53!
= Preset Name Up to 16 characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics SMP 300 Series and is the answer not in the manual?

Extron electronics SMP 300 Series Specifications

General IconGeneral
BrandExtron electronics
ModelSMP 300 Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals