SMP 300 Series • Remote Communication and Control 128
Command Function SIS Command
(Host to Device)
Response
(Device to Host)
Additional Description
Input Adjustments (Input 3 only) continued
Horizontal Start
Set horizontal start E
3*
X60$
HSRT
}
Hsrt
03*
X60$] Set the horizontal start value for
input 3 to
X60$
.
Increment horizontal
start
E
3+HSRT
}
Hsrt
03*
X60$] Increment the horizontal start
value
X60$
for input 3 by one
pixel.
Decrement horizontal
start
E
3-HSRT
}
Hsrt
03*
X60$] Decrement the horizontal start
value
X60$
for input 3 by one
pixel.
View horizontal start E
3
HSRT
} X60$] View the horizontal start value
X60$
of input 3.
KEY:
X60$
= Horizontal and vertical start 0 to 255 (default: 128)
Vertical Start
Set vertical start
E
3*
X60$
VSRT
}
Vsrt
03*
X60$]
Set the vertical start value of
input 3 to
X60$
.
Increment vertical start
value
E
3+VSRT
}
Vsrt
03*
X60$]
Increment the vertical start value
X60$
for input 3 by one pixel.
Decrement vertical start
value
E
3-VSRT
}
Vsrt
03*
X60$]
Decrement the vertical start
value
X60$
for input 3 by one
pixel.
View vertical start E
3
VSRT
} X60$]
View the vertical start value
X60$
of input 3.
KEY:
X60$
= Horizontal and vertical start 0 to 255 (default: 128)
Active Pixels
Set active pixels E
3*
X60&
APIX
}
Apix03*
X60&] Set the active pixels per line for
input 3 to
X60&
.
Increment active pixels E
3+APIX
}
Apix03*
X60&]
Increment the active pixels
X60&
for input 3 by one pixel.
Decrement active pixels
E
3-APIX
}
Apix03*
X60&]
Decrement the active pixels
X60&
for input 3 by one pixel.
View active pixels
E
3
APIX
} X60&]
View the active pixels value
X60&
of input 3.
KEY:
X60&
= Active pixels Up to +512 of the default value for the detected resolution
Active Lines
Set active lines
E
3*
X60^
ALIN
}
Alin03*
X60^]
Set active lines for input 3 to
X60^
.
Increment active lines E
3+ALIN
}
Alin03*
X60^]
Increment the active lines
X60^
for input 3 by one pixel.
Decrement active lines E
3-ALIN
}
Alin03*
X60^]
Decrement the active lines
X60^
for input 3 by one pixel.
View active lines E
3
ALIN
} X60^]
View the active lines value
X60^
of input 3.
KEY:
X60^
= Active lines Up to +256 of the default value for the detected resolution

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics SMP 300 Series and is the answer not in the manual?

Extron electronics SMP 300 Series Specifications

General IconGeneral
BrandExtron electronics
ModelSMP 300 Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals