16
A/D converter
16-bit (auto ranging)
Dynamic range >90 db
Frequency resolution
1600, 3200 lines (0.0625 Hz up to 12.5 Hz depending on the
configured lowpass frequency)
Balancing
1 or 2 plane balancing
Weight positions: continuous (0 to 359°) or discrete (4 to 99
positions)
Remove trial weights: yes/no
Balancing measurement type
Acceleration, velocity, displacement
Measurement
Peak, Peak Peak, RMS
Balancing units
g, mm/s, inch/s, µm, mil
Weights units
g, oz (up to 99 999,99 g / oz)
Automatic measuring point detection (RFID)
Radio frequency
13.65 MHz
RFID standard
ISO 15693
Product must only be operated
in
European Union (EU), Switzerland, USA, Canada, Australia
General
Separate measurements
Temperature, rotational speed, headset (envelope signal)
Keyboard
Membrane keyboard with 21 keys
Display
Backlit graphic display (LCD) 128x 64 pixels,
dimension 55 x 33 mm
Memory
1600 measuring points plus 270 time signals (maximal 300 time
signals)
Power supply
NiMh 2 000 mAh
Voltage 6V
Operation time approx. 6 to 8 hours (charging time for empty battery
approx. 4 h)
Size and weight
230 x 70 (53) x 45 (53) mm (L x W x H), approx. 500 g (including
battery)
Temperature range
0 to 50 °C (operating temperature)
0 to 40°C (to load the charger)
-20 to +70 °C (storage and transport temperature)
Operation time
approx. 6 to 8 hours continuous operation

Table of Contents