Special information
7 Special information
7.1 Characteristic values
Detector III can store up to 4 different (or same just as well) characteristic values
per measuring point. The following characteristic values can be selected:
Characte
ristic
value
Meaning
ISO 10816
RMS value of vibration velocity
Frequency range: 10 Hz to 1 kHz
Unit: mm/s
v
sel
RMS value of vibration velocity with freely selectable upper and lower limiting frequency
Frequency range: 0.3 Hz to 20 kHz (depending on the lowpass frequency)
Unit: mm/s
a
eff
RMS value of acceleration in vibration
Frequency range: 2 Hz to 20 kHz (depending on the lowpass frequency)
Unit: g
a
sel
RMS value of acceleration in vibration with freely selectable upper and lower limiting
frequency
Frequency range: 0.1 Hz to 20 kHz (depending on the lowpass frequency)
Unit: g
d
eff
Demodulation signal of acceleration in vibration with switchable low-pass
Frequency range: 0.1 Hz to 20 kHz (depending on the lowpass frequency)
Unit: g
d
sel
RMS value of demodulation in vibration with freely selectable upper and lower limiting
frequency
Frequency range: 0.1 Hz to 20 kHz (depending on the lowpass frequency)
Unit: g
T
Temperature
Range: -20°C to +550°C
Unit: °C
Crest factor
Ratio between peak value and RMS value (Crest factor = peak value / RMS value)
Universal
Universal characteristic value
Range: 0 to 99999
Unit: none
In addition to the aforementioned characteristic values, you can
also measure rotational speed.