65
Trendline 3
Click on and
edit the settings.
Click on OK.
Measured values
In the Measured data section you can display the acquired data numerically and
graphically. For more information refer to Measured values .
4.4.4 Setting characteristic values
You can create the following characteristic values per measuring point:
ISO 10816,
A
sel
and A
eff
,
D
sel
and D
eff
,
Temperature,
V
sel
,
Crest factor and
Universal.
Please also observe the information in the "Frequency selective characteristic
values " section.
Characteristic values can be changed until they have been sent to
the Detector for the first time. After that the characteristic values turn
grey in the tree and cannot be altered anymore. Otherwise, the
measuring results could not be compared.
To add a new characteristic value, right-click the measuring point the
characteristic value is meant for and, after that, on New sub-item. Alternatively,
you can do it via System > New sub-item or via . The following window now
opens: