3 System Introduction
3
FOCUSED PHOTONICS INC
Item Parameter
Range Offset ≤±1%F.S.(24h)
Linear Offset ≤±1%F.S.
Gaseous Pollutants
Response Time ≤30s
Measurement
Distance
(0.5~15)m
Dust Density
Range
(0~100)mg/m
3
,(0~15)g/m
3
Particulates
Measurement
Precision
2%F.S.
Measurement
Range
(0~400)℃ Temperature
Measurement
Precision
±0.5%F.S.
Measurement
Range
(-10~10)kPa Pressure
Measurement
Precision
±0.5%F.S.
Measurement
Range
(1~40)m/s
Gas Parameter
Flow Rate
Measurement
Precision
≤1%F.S.
OMA-2000 Input 9-CH analog input channel, 2-CH analog input
channel
OMA-2000
Output
8-CH analog output channel
16-CH digital output channel
1-CH RS232 port
1-CH RS485 port
4-CH RS232/GPRS port IPC
Windows 2000 OS
Date Acquisition
and Processing
System Software CEMS-2000 Software
Power 220V AC/50Hz 1kW (not including tracing
pipe and compressor)