Press and hold the wire retract button
After pressing the wire retract button, the wire electrode is retracted
by 1 mm (0.039 in.).
After a short pause, the wirefeeder continues to retract the wire elec-
trode - if the wire retract button remains pressed, the speed increases
every second by 10 m/min (393.70 ipm) up to the preset wire retract
speed.
Method 2
Retracting the wire electrode in 1 mm increments (0.039 in. increments) –
always press the wire retract button for less than one second (tap)
IMPORTANT! Do not allow long lengths of wire electrode to be retracted,
as the wire electrode is not wound onto the wirespool when retracted.
IMPORTANT! If there was a ground earth connection with the contact tip
before the wire retract button was pressed, the wire electrode will be re-
tracted when the button is pressed until it is short-circuit-free - it retracts
by no more than 10 mm (0.39 in.) with each press of the button.
If the wire electrode is to be retracted further, the wire retract button
must be pressed again.
(4) Wire threading button
For threading the wire electrode into the torch hosepack with no accom-
panying flow of gas or current
-
While the button is pressed, the wirefeeder runs at the preset feeder
inching speed
Wire threading can be performed using one of two methods:
Method 1
Threading the wire electrode using the preset feeder inching speed:
-
Press and hold the wire threading button
After pressing the wire threading button, the wire electrode is thread
in by 1 mm (0.039 in.).
After a short pause, the wirefeeder continues to feed in the wire elec-
trode - if the wire threading button remains pressed, the speed in-
creases every second by 10 m/min (393.70 ipm) up to the preset feed-
er inching speed.
If the wire electrode comes into contact with a ground earth connec-
tion, the wirefeeding will be stopped and the wire electrode will be re-
tracted again by 1 mm (0.039 in.).
Method 2
Threading the wire electrode in 1 mm increments (0.039 in. increments) -
always press (tap) the wire threading button for less than 1 second
If the wire electrode comes into contact with a ground earth connection,
73