WF 25i Robacta Drive
WF 25i Robacta
Drive /G
Welding current at 10 min/40°C
M21 (EN 439)
C1 (EN 439)
60 % ED* / 260 A
100 % ED* / 210 A
60 % ED* / 320 A
100 % ED* / 260 A
Wire diameter 0.8 - 1.6 mm
0.032 - 0.063 inch
Supply voltage 60 V DC
Nominal current 3 A
Wire speed 1 - 25 m/min
39.37 - 984.25 ipm
Voltage measurement (V-Peak) for
mechanically driven welding torches
141 V
The product conforms to the requirements of the IEC 60974-7 standard
* D.C. = Duty cycle
WF 25i Robacta
Drive /W
Welding current at 10 min/40 °C
M21 (EN 439)
C1 (EN 439)
100 % ED* / 500 A
100 % ED* / 500 A
Wire diameter 0.8 - 1.6 mm
0.032 - 0.063 inch
Minimum coolant flow Q
min
1 l/min
0.26 gal (US) / min
Minimum coolant pressure p
min
3 bar
43 psi
Maximum coolant pressure p
max
5 bar
72 psi
Supply voltage 60 V DC
Nominal current 3 A
Wire speed 1 - 25 m/min
39.37 - 984.25 ipm
Voltage measurement (V-Peak) for
mechanically driven welding torches
141 V
The product conforms to the requirements of the IEC 60974-7 standard
* D.C. = Duty cycle
186