EasyManua.ls Logo

Fujitsu AJ 126LELDH Series - Wall Mounted Type

Fujitsu AJ 126LELDH Series
1092 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-15. Wall mounted type
Model name
ASA004GCGH ASA007GCGH ASA009GCGH
Power supply 230 V ~ 50 Hz
Available voltage range 198—264 V
Capacity
Cooling
kW 1.1 2.2 2.8
Btu/h 3,800 7,500 9,600
Heating
kW 1.3 2.8 3.2
Btu/h 4,400 9,600 10,900
Input power W 12 16 20
Fan
Airflow rate
HIGH
m
3
/h (l/s)
450 (125) 550 (153) 610 (169)
MED—HIGH 430 (119) 510 (142) 560 (156)
MED 400 (111) 470 (131) 510 (142)
MED—LOW 380 (106) 410 (114) 440 (122)
LOW 360 (100)
QUIET 310 (86)
Type × Q'ty Cross flow × 1
Motor output W 30
Sound pressure level*
HIGH
dB (A)
31 34 37
MED—HIGH 30 32 35
MED 28 30 32
MED—LOW 27 28 29
LOW 26 26
QUIET 22
Heat exchanger type
Dimensions (H × W × D)
mm
320 × 630 × 20
Main: 320 × 630 × 20
Sub: 84 × 630 × 13.3
Length 630
Fin pitch 1.1
Main: 1.1
Sub: 1.4
Rows × Stages 2 × 20
Main: 2 × 20
Sub: 1 × 4
Pipe type (Material) Grooved H-pin (Copper)
Fin
Type (Material) Slit (Aluminum)
Surface treatment Hydrophilic coating
Air filter Net material PP honeycomb
Enclosure
Material Plastic
Color
White
Approximate color of Munsell N9.25/
Dimensions
(H × W × D)
Net Main body
mm
268 × 840 × 203
Gross 270 × 884 × 336
Weight
Net
kg
8.0 8.5
Gross 10.5 11.0
Connection pipe diameter
Liquid (Flare)
mm (in)
Ø 6.35 (Ø 1/4)
Gas (Flare) Ø 9.52 (Ø 3/8)
Drain hose I.D.: Ø 13.8 (9/16); O.D.: Ø 15.8 to Ø 16.7 (5/8 to 11/16)
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length: 7.5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*: Sound pressure level:
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.