EasyManua.ls Logo

Fujitsu AJ 126LELDH Series - Piping to Outdoor Unit

Fujitsu AJ 126LELDH Series
1092 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-1. Piping to outdoor unit
¢
Piping method
Opening the knockout hole
CAUTION
Be careful to prevent panel deformation or damaged while opening the knockout hole.
To prevent cutting of the wiring after the knockout hole was opened, remove the burrs along the
edge. In addition, to prevent rusting, painting the edge with rust preventive paint is recommend-
ed.
The piping can be connected from 3 directions of the front, the lateral side, and the bottom.
When connecting at the bottom, remove the service panel and piping cover on the front of the out-
door unit, and open the knockout hole provided at the bottom corner of the piping outlet.
When cutting the slits, use a steel saw and cut out the 2 slits as shown in Fig. B and Fig. C.
Unit: mm
Service panel
Front
Lateral
9221
61 100
94 21
61 94
60 12
14 90
Top view of
the base
Fig. A
Front connection
Lateral connection
Bottom connection
Slit
Slit
Fig. B
Fig. C
Bottom connection
3-1. Piping to outdoor unit - (06-35) - 3. Piping connection