EasyManua.ls Logo

Fujitsu AJ 126LELDH Series - Indoor Unit (Setting by Wireless Remote Controller)

Fujitsu AJ 126LELDH Series
1092 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-4. Indoor unit (setting by wireless remote controller)
CAUTION
This setting changes the function settings used to control the indoor unit according to the installa-
tion conditions. Incorrect settings can cause a product malfunction.
After the power is turned on, perform the “Function setting” according to the installation conditions
using the remote controller.
The settings may be selected between the following two: Function number or Setting number.
Settings will not be changed if invalid numbers or setting numbers are selected.
¢ Preparation
1. Before turning on the power of indoor unit, reconfirm following items:
Piping air tight test and vacuuming have been performed firmly.
There is no wiring mistake.
2. Turn on the power of indoor units.
By turning on the power, the indoor units initialize EEV.
Indoor units Indoor units
Breaker ON
Before proceeding the function setting, refer to the following sections and perform necessary steps:
"Button name and function" on page 07-17
"Entering function setting mode" on page 07-18
"Selection and confirmation of custom code" on page 07-18
¢ Indoor unit function setting
1. Press the MODE button to enter the function setting mode.
2.
Press the SET TEMP. or button to adjust the function number.
Each time the MODE button is pressed, it switches between the left digit and the right digit.
Change digit
2-4. Indoor unit (setting by wireless remote controller)
- (07-87) - 2. Function settings
FUNCTION
SETTINGS
FUNCTION
SETTINGS

Table of Contents

Related product manuals