2-12. Compact floor type (EEV external model)
Model name
AGE004GCEH AGE007GCEH AGE009GCEH
Power supply 230 V ~ 50 Hz
Available voltage range 198—264 V
Capacity
Cooling
kW 1.1 2.2 2.8
Btu/h 3,800 7,500 9,600
Heating
kW 1.3 2.8 3.2
Btu/h 4,400 9,600 10,900
Input power W
12/14*
1
16 17
Fan
Airflow rate
HIGH
m
3
/h (l/s)
380/430*
1
(106/119)
470 (131) 500 (139)
MED—HIGH 350 (97) 420 (117) 450 (125)
MED 320 (89) 390 (108) 400 (111)
MED—LOW 310 (86) 360 (100)
LOW 280 (78) 330 (92)
QUIET 210 (58) 270 (75)
Type × Q'ty Cross flow × 2
Motor output W 16 × 2
Sound pressure level*
2
HIGH
dB (A)
35/36*
1
37 38
MED—HIGH 33 35 36
MED 31 33 34
MED—LOW 30 31
LOW 28 29
QUIET 22
Heat exchanger type
Dimensions (H × W × D)
mm
378 × 550 ×26.6
Length 550
Fin pitch 1.2
Rows × Stages 2 × 18
Pipe type (Material) Grooved H-pin (Copper)
Fin
Type (Material) Slit (Aluminum)
Surface treatment Hydrophilic coating
Air filter Net material PP plain weave
Enclosure
Material Plastic
Color
White
Approximate color of Munsell 5Y 9/0.5NN
Dimensions
(H × W × D)
Net
mm
600 × 740 × 200
Gross 700 × 820 × 310
Weight
Net
kg
14.5
Gross 18 18.5
Connection pipe diameter
Liquid (Flare)
mm (in)
Ø 6.35 (Ø 1/4)
Gas (Flare) Ø 9.52 (Ø 3/8)
Drain hose I.D.: Ø 13.8 (9/16); O.D.: Ø 15.8 to Ø 16.7 (5/8 to 11/16)
EV kit (Option) UTR-EV09XB
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length: 7.5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*1: This value is “Cooling operation/Heating operation”.
*2: Sound pressure level:
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.