2-18. Simple remote controller (UTY-RSR, UTY-RHR)
¢ Remote controller address confirmation
1. Select the “15” in Menu 2-F1 Settings. Then press the “
” button.
2. You can check current allocation of 2-wire remote controller address (system number and unit
number).
System number
Address automatically
allocated
Unit number
Press the “
” button to return to the Menu 2-F1 item selection screen.
NOTE: In the case of automatic address settings, do not change the remote controller address for
the indoor unit, and keep it at the initial setting of “0”. Addresses will be automatically set
when initially starting up this unit.
¢ Master or slave setting of remote controller
1. Select the “06” in Menu 2-F1 Settings. Then press the “
” button.
2.
Select the “0: Master” or the “1: Slave” with the TEMP. “ ” or TEMP. “ ” button.
2-18. Simple remote controller (UTY-RSR
, UTY-RHR)
- (07-127) - 2. Function settings
FUNCTION
SETTINGS
FUNCTION
SETTINGS