3. Press the ENTER button. If there is no problem, return to Menu 2 items selection screen. In the
case of settings at initial booting, display Monitor mode screen.
If there is 0 or more than 2 Master units, the number will be displayed.
• If “Master” is 0, press the ENTER button to return to the Menu 2 item selection screen.
• If “Master” is more than 2, press the ENTER button to return to the screen in previous step.
• If “Master” is 0 or more than 2, press the MENU button to return to the Menu 2 item selection
screen.
NOTE:
Set only one master remote controller.
¢ Indoor unit address verification
1. Select the “10” in Menu 2 Settings. Then press the ENTER button.
2. From remote controller with smallest 2-wire remote controller address of the remote controller
group will be displayed.
Indoor units displayed can be switched by + or - button.
(a) Refrigerant circuit address (00 to 99)
(b) Indoor unit address (00 to 63)
(c) System number (002: Indoor unit)
(d) Remote controller address (01 to 32)
3. Press the MENU button to return to the Menu 2 item selection screen.
2-17. Wired remote controller (UTY-RLR
)
- (07-126) - 2. Function settings
FUNCTION
SETTINGS
FUNCTION
SETTINGS