System diagram
1 remote controller:
A
Indoor unit
Remote controller
2 remote controllers:
Primary
Secondary
B C
Indoor unit
Remote controllers
A, B, C: Remote controller cable
A ≤ 500 m;B + C ≤ 500 m
¢
Electrical wiring
1 remote controller:
Remote controller
1 (Red): 12 V
2 (White): Signal
3 (Black): COM
Indoor unit
Remote
controller
1 2 3
1 2 3
G
G
2 remote controllers:
Remote controllers
1 (Red): 12 V
2 (White): Signal
3 (Black): COM
Primary Secondary
Indoor unit
1 2 3
1 2 3 1 2 3
Remote
controller
G
G
G
¢ Dimensions
Unit: mm
Front View Side View Rear View
120
75
49
39
23.5
14
4
11
4.5
12.5
hole x 2
hole x 2
8
60
6
18
9
47.5
83.5