Restriction when install
Be sure following restriction.
Installation angle
Place the Separation tube horizontally or vertically so that the refrigerant separates evenly.
Horizontal
ProhibitedProhibitedGood Good
Vertical
CAUTION
If it is placed horizontally, keep it within allowable mounting angle below. Otherwise, it will not
separate the refrigerant evenly, causing a reduction in performance.
±15°
Prohibited
Good:
Prohibited
During piping work, apply nitrogen gas while brazing the pipes. If pipes are brazed without ap-
plying nitrogen gas, it will create a large amount of oxidation film, which will cause a critical
malfunction.
To prevent moisture or foreign matter from entering during work, do not leave the piping open.
Refer to the installation manual supplied with the outdoor unit for airtightness test and evacu-
ation procedures.