¢ Components location
Components related to automatic address setting are located on the outdoor unit PCB.
Set the functions of an outdoor unit with the push buttons (SW107, SW108, and SW109) while ob-
serving the 7-segment LED lamps (LED105 and LED104) on the PCB.
Outdoor unit PCB
Set 5
LED101
(GREEN)
SW107 SW108 SW109
SW106 SW105
POWER
MODE
MODE
/EXIT
LED105 LED104
REF AD
SET1 SET2
LED102
(RED)
ERROR
SELECT ENTER
X 10 X 1
LED lamp
7-segment LED lamp
Rotary switch
DIP switch
Push button
DIP switch
NOTE:
For details of DIP switch set 5, refer to "Terminal resistor setting" on page 07-63.